Whirlpool Maytag WVU37UC6FS 설치 지침 및 사용 및 관리 매뉴얼 - 페이지 7

{카테고리_이름} Whirlpool Maytag WVU37UC6FS에 대한 설치 지침 및 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool Maytag WVU37UC6FS 36 페이지. 30" (76.2 cm) and 36" (91.4 cm) range hood

Whirlpool Maytag WVU37UC6FS 설치 지침 및 사용 및 관리 매뉴얼
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
7" (17.8 cm) Round Vent System
Vent Piece
45° elbow
90° elbow
7" (17.8 cm) wall cap
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
to 7" (17.8 cm)
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
to 7" (17.8 cm) 90° elbow
Example vent system
7" (17.8 cm) round
90˚ elbow
2 ft (0.6 m)
Maximum Recommended Length
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of 7" (17.8 cm) system
Round
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
0.0 ft
(0.0 m)
4.5 ft
(1.4 m)
5.0 ft
(1.5 m)
Wall cap
6 ft (1.8 m)
= 50 ft (15.2 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)
3¹⁄
" x 10" (8.3 cm x 25.4 cm) Vent System
4
Vent Piece
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
90° elbow
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
flat elbow
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
wall cap
Example vent system
¼
3
" x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
Maximum Recommended Length
1 - 90° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of 3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
system

Electrical Requirements

Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
(latest edition), or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local
codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
5.0 ft
(1.5 m)
12.0 ft
(3.7 m)
0.0 ft
(0.0 m)
6 ft (1.8 m)
Wall cap
= 35 ft (10.7 m)
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)
= 13.0 ft (3.9 m)
7