Whirlpool Slide-Out Range Hood 설치 및 사용 설명서 - 페이지 7

{카테고리_이름} Whirlpool Slide-Out Range Hood에 대한 설치 및 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool Slide-Out Range Hood 36 페이지. 30" (76.2 cm) and 36" (91.4 cm) slide-out range hood

For GZ or IH model series:
WARNING: To reduce the risk of fire or electrical shock, do not
use this fan with any solid state speed control device.
For KWVU model series:
This fan is suitable for use with solid state speed controls.
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575

Prepare Location

It is recommended that the vent system be installed before
the range hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for vent fittings.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or non-
vented.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4. Using 2 or more people, lift range hood onto covered surface.

Electrical Requirements

INSTALLATION INSTRUCTIONS

A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate.
The model/serial plate is located behind the filter on the rear
wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
Range Hood Cabinet Cutout
1. Determine and clearly mark a centerline on the underside of
the cabinet.
A. Centerline
2. Measure and mark lines as shown for your size of range
hood. Use a saber saw or keyhole saw to cut an opening
through the underside of the cabinet.
"
1
(3.8 cm)
"
9
(23.3 cm)
30" (76.2 cm) hood - 13
36" (91.4 cm) hood - 16
The finished cutout size will be:
30" (76.2 cm) range hood - 9
36" (91.4 cm) range hood - 9
A
"
(33.2 cm)
"
(40.8 cm)
" x 26 " (23.3 cm x 66.4 cm)
" x 32 " (23.3 cm x 81.6 cm)
7