4,
Install the 6 mm nuts to the outside top or outside back
(alternate location on some models) of the range hood at the
proper location for the selected motor system.
•
Two 6 mm nuts are required for the single motor system.
Clip nuts into the small square notches located at the left
and right end of the square vent opening.
Five 6 mm nuts are required for the dual motor system.
Clip nuts into the small square notches, one located in the
front of the square vent opening and the other four
located at the left and right ends of the square vent
opening.
A
Dual Blower Motor Assembly
A
,//
A. Wiring connection
2. Slide the left mounting plate flange under the motor mounting
bracket.
5,
A. Clip nut locations
for dual motor assembly (5)
B. Clip nut locations
for single motor assembly (2)
Mount range hood using the Installation Instructions that
came with your range hood model.
1,
Hood Bo
f Moso "
Install the range hood blower motor assembly inside the
range hood canopy with the wiring connection to the left for
the single motor system and to the front or top for the dual
motor system.
Single Blower Motor Assembly
3,
A
A. Wiring connection
/
/
/
/
A
B
A. Motor mounting bracket
B. Mounting plate left flange
Run the power supply wires and connector through the hole
in the right end of the motor mounting plate.
A
//
B
A. Motor mounting plate hole
B. Power supply wires and connector