Whirlpool WVU17UC0F 설치 지침 및 사용 및 관리 매뉴얼 - 페이지 5
{카테고리_이름} Whirlpool WVU17UC0F에 대한 설치 지침 및 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool WVU17UC0F 28 페이지.
Installation Clearances
A
B
E
A. 24" (61 cm) minimum distance from electric cooking surface
24" (61 cm) minimum distance from gas cooking surface
30" (76.2 cm) suggested maximum above the cooking surface
B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop
C. 30" (76.2 cm) minimum cabinet opening width for 30"
(76.2 cm) models and 36" (91.4 cm) minimum cabinet
width for 36" (91.4 cm) models
D. 12" (30.5 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height
Venting System
Venting Methods
NOTES:
Flexible vent is not recommended. Flexible vent
■
creates both back pressure and air turbulence
that greatly reduce performance.
The vent system is optional for this model.
■
Vent system can terminate either through the roof or wall.
Use 3
/
" x 10" (8.3 x 25.4 cm) rectangular with a maximum
1
4
vent length of 35 ft (10.7 m).
C
D
Top Venting
B
A
A. 3
/
" x 10" (8.3 x 25.4 cm)
1
4
rectangular vent through the
roof (purchased separately)
B. Roof cap with damper
(purchased separately)
Cold Weather Installations
An additional backdraft damper should be installed to
minimize backward cold air flow and a thermal break should
be installed to minimize conduction of outside temperatures
as part of the vent system. The damper should be on the cold
air side of the thermal break.
The break should be as close as possible to where the
vent system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup
air systems when using ventilation systems greater than
specified CFM of air movement. The specified CFM varies
from locale to locale. Consult your HVAC professional
for specific requirements in your area.
Venting Requirements
Vent system must terminate to the outdoors, except
■
for non-vented (recirculating) installations.
Do not terminate the vent system in an attic
■
or other enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
■
Use 3
/
" x 10" (8.3 x 25.4 cm) rectangular metal
1
■
4
vent, depending on your installation requirement.
Rigid metal vent is recommended. Plastic or metal
foil vent is not recommended.
The length of vent system and number of elbows should
■
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
■
Make sure there is a minimum of 24" (61 cm) of straight
■
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
■
Use clamps or duct tape to seal all joints in the vent system.
■
The vent system must have a damper. If roof or wall cap has
■
a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening
■
around the cap.
Wall Venting
A
B
A. 3
/
" x 10" (8.3 x 25.4 cm)
1
4
rectangular vent through
the wall or out the top
(purchased separately)
B. Wall cap with damper
(purchased separately)
5