Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
a UL listed or CSA approved
A. Terminal box
B. Knockout
C. Terminal box cover
4. Run home power supply cable through strain relief
into terminal box.
G
A. Home power supply cable
B. UL listed or CSA
approved strain relief
C. UL listed wire connectors
5. Use UL listed wire connectors and connect
black wires (E) together.
/
" strain relief.
1
2
C
B
A
A
B
C
D
E
F
D. White wires
E. Black wires
F. Green (or bare) and
yellow-green ground wires
G. Terminal box
6. Use UL listed wire connectors and connect
white wires (C) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Vent Covers
NOTE: Remove protective film from the vent covers.
1. When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with (2) 4.2 x 8 mm screws.
C
D
A. Upper vent cover
B. Lower vent cover
C. 4.2 x 8 mm screws
D. Bracket
NOTE: For vented installations, the upper vent cover
may be reversed to hide slots.
A
B
9