00_:_
Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2. Remove the grease filter. See "Range Hood Care" section.
3. Level the range hood and tighten upper mounting screws.
4. Install 2 - 5 x 45 mm lower mounting screws and tighten.
1=
Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A
B
\
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations
only:
1. Fit vent system over the exhaust outlet.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket using
4 - 4.2 x 8 mm screws.
2=
3=
4.
5.
6.
7=
8=
B
C
A.Assembly screws
B. Air deflector
C. Duct cover bracket
Measure from the bottom of the air deflector to the bottom of
the hood outlet.
/
...................................................
A
B
D .......................
i_ _
| ...............
A.Air deflector
D. Vent duct
B. Ventclamp
E. Exhaust outlet
C. X = length to cut vent duct
Cut the duct to the measured size (X).
Remove the air deflector.
Slide the duct onto the bottom of the air deflector.
Place the assembled air deflector and duct over the exhaust
outlet from the hood.
Reassemble the air deflector to the duct cover bracket with
the 4 assembly screws.
Seal connections
with vent clamps.