Backyard Pro 554LPG72RD 사용자 설명서 - 페이지 10

{카테고리_이름} Backyard Pro 554LPG72RD에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Backyard Pro 554LPG72RD 17 페이지. Liquid propane grill roll dome
Backyard Pro 554LPG72RD에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (6 페이지)

Backyard Pro 554LPG72RD 사용자 설명서
10 |General Information and Instructions
WARNING:
1. Do not connect this grill to any unregulated sources of propane.
2. Before each use, check the gas hose for excessive abrasion or wear, or cuts. Replace a hose assembly showing those signs with the
hose assembly specified in the parts list before using the grill.
3. Always perform the Leak Test listed below before using your grill for the first time, if the cylinder has been changed, any gas
components have been changed, the regulator flow-limiting device has been activated, or after a long period of non-use.
4. Do not attempt to connect this grill to the LP system of a motor home or trailer.
LEAK TESTING THE REGULATOR, VALVES, HOSES AND CONNECTIONS
1. Ensure the LP cylinder valve and all burners are "Off".
2. Ensure the LP cylinder is connected to the regulator.
3. If the information in1 & 2 is not followed exactly, a fire causing death or serious injury may occur.
4. Mix up a solution of 50% water and 50% liquid dish soap. Do not use any household cleaner solution.
5. Open the LP tank valve by turning the hand wheel counterclockwise one turn. If you hear a rushing sound, turn the gas off
immediately. In that case, there could be a leak at the connection. Reconnect the cylinder to the regulator.
6. Spray or brush on the solution covering the following areas: regulator and cylinder connection, gas hose connections to the
regulator, all gas hoses, all gas hose connections to the burners including the main and side burners.
7. Growing bubbles on any of the parts and connections listed above indicate a gas leak. Immediately shut off the LP tank valve by
turning the valve clockwise. Retighten the connections or order replacement parts as needed. Continue to test as necessary until
no leaks are detected.
8. Close the LP tank valve by turning the hand wheel clockwise.