CALEFFI SENSONICAL ULTRA CAL19185MU 매뉴얼 - 페이지 6

{카테고리_이름} CALEFFI SENSONICAL ULTRA CAL19185MU에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CALEFFI SENSONICAL ULTRA CAL19185MU 8 페이지. Heat meter

3 - Statistical level
...
(1)
available on CAL19185MI
Error codes
When the instrument detects an error it displays the error symbol and the relevant code.
The error can also be displayed by selecting item 8 "error message" on the main level.
The instrument detects eight causes of error, indicated by the number 1 in the eight-digit code of the
error message. These causes of error can also occur together. The position of the number "1" in the
error message corresponds to a cause, as specified below.
5
Temperature difference
6
Days of operation since setting
7
Probe model and installation position
(R=return, U=inlet)
8
M-bus address
9
Serial number of the heat meter
10 Firmware/software release
1
Date of last readout alternating with relative heating/cooling
energy consumption and pulse input meters
2-16 Monthly values: date of last reading alternating with relative
heating/cooling energy consumption and pulse input meters
6
(1)
1)