Environmental Requirements
Printer System Requirements
Environmental Factor
Temperature
Humidity
Altitude (above sea level)
Power Consumption (approximate)
Energy Star (eStar) compliant. See
Power Requirements for more
information
Noise (Approximate sound pressure
level at operator position)
Nominal Voltage (processor)
Heat Output
NOTE 1: If above 90 Degrees F (32 Celsius), reduced relative humidity is required to maintain the
specific performance.
NOTE 2: For altitudes above 10,000 feet, equipment shutdown rates may increase.
FreeFlow DocuSP Print Server power requirements
Section
Platform
Single Phase
Nominal Voltage
Xerox Receptacle part number
Customer provided receptacle (or equivalent)
Frequency
FreeFlow DocuSP Print Server power cord
length
Length of cables (2) connecting the Controller
to the Print Engine
Dedicated use of 15 ampere outlet
Receptacle diagram (XNA only, All others:
Flying-leads)
Power
NOTE 1: Surge protection is strongly recommended for network controller installations and is the
responsibility of the customer.
NOTE 2: The power source for the network controller must be continuous and not interrupted by
an onsite power failure.
Printer system power requirements
The electrical outlet must be located within 6 feet (1828 mm) to the right of the right rear corner of
the main processor, or no more than 3 feet (914 mm) to the left of the left rear corner of the main
processor (when facing the machine).
The outlet/circuit cannot be shared with any other devices or equipment.
Recommended
Minimum
70 degrees F (22
50 degrees F
Celsius)
(10 Celsius)
45% RH
15% RH
0 feet (0 m)
Standby: 375w
Low Power:
120w
Sleep Mode:
13w
Standby (dbA)
54.4
208 VAC
187VAC
Standby:
1500 BTU/Hr
Specification
SUN Ultra 20
2 wire, plus ground
8 Ampere
100-240 volts AC (-10% to +6%)
600S3704
NEMA Part No 5-15R
50/60 Hz single phase
10 feet /3 M
10 feet/3 M
15 feet/5 M
5-15 R
150 W maximum
Maximum
90 degrees F
(32 Celsius)
85% RH
10,000 feet
(3,048 M)
Running:
1.92Kw
Running (dbA)
78.7
Peak (dbA) 81.5
254VAC
50/60 Hz run is
7680 BTU/Hr
16