Xerox Versant 2100 Press 고객 기대치 및 설치 매뉴얼 - 페이지 42
{카테고리_이름} Xerox Versant 2100 Press에 대한 고객 기대치 및 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Xerox Versant 2100 Press 49 페이지. Entry production color presses
Xerox Versant 2100 Press에 대해서도 마찬가지입니다: 보안 매뉴얼 (45 페이지)
Installation
Total amount of
Total number of required circuits
amps required
14.7 amps
Two 20 amp circuits:
One 20 amp circuit for the Print Server and
One 20 amp circuit for the finishing devices
Recommended Wall Receptacle Placement
The recommended wall receptacle placement for the print server,
Advanced HCF, the press, and its accessories are shown in the following
illustration. This is for USA receptacles only. It is recommended that
receptacles be grouped as shown in relation to the press.
The following illustration shows a full configuration consisting of the print
server, Advanced HCF, the press, Interface Module, GBC AdvancedPunch Pro,
2 High Capacity Stackers, Booklet Maker Finisher with C/Z Folder, and
SquareFold Trimmer Module.
Electrical Installation Considerations
Press Electrical Considerations
Ground Fault Protection is provided which meets Xerox internal safety
requirements and exceeds the Industry Standards for Information
Technology Equipment.
The electrical outlet must be located within 6 feet (1.83 m) to the right
of the right rear corner of the left module, or no more than 3 feet (0.914
m) to the left of the left rear corner of the left module (when facing the
equipment)
The power cord must have sole use of the circuit. The outlet/circuit
cannot be shared with any other devices or equipment
Advanced HCF should be placed within 6 feet (1.83 meters) of wall
outlets.
Advanced HCF should have its own power cord and must be plugged
into an outlet separate from the press. Ensure that there are enough
wall outlets.
Electrical Considerations for Optional Devices
Electrical requirements and space requirements must be satisfied prior
to equipment delivery
Optional accessories should be placed within 6 feet (1.83 meters) of wall
outlets.
Most optional devices have their own power cord and must be plugged
into an outlet separate from the print engine. Ensure that there are
enough wall outlets for each required accessory.
Electrical Considerations for Print Servers
Electrical requirements and space requirements must be satisfied prior
to equipment delivery
The print server should be placed within 6 feet (1.83 m) of the wall
outlet.
Ensure that there is an available wall outlet for the print server.
Information Applicable to All Electrical Devices
Extension Cord Information
Customer Expectation and Installation Guide
OHCF using 4 (NEMA 5-20R) receptacles
using 6 (NEMA 5-20R) receptacles
Periodically extension cords may be needed. Electrical and local building
and fire codes must be adhered to in terms of length of cord, conductor
size, and grounding. An extension cord may serve only one device. Plug
strips are not extension cords and may be used for computer applications.
Acceptable Circumstances for Using Extension Cords
Extension cords may be used under the following circumstances:
Extension cords may be used to facilitate demo situations where the
customer does not have an outlet receptacle at the location of the demo
placement. All electrical and code requirements apply.
Where a temporary condition exists (90 days) at the customer site
before a permanent outlet receptacle is installed, an extension cord set
may be used to get the customer up and running. Typical situations
include customer moves, remodeling, and recovery from fires or other
facility emergencies.
For most copy and facsimile machines requiring 20 amp service or less
and where permitted by the Authority Having Jurisdiction, extension
cord sets may be used without regard to length of time in service.
Extension Cord Requirements
Extension cords must meet the following requirements:
The customer must notify the appropriate agencies (Authority Having
Jurisdiction) such as the local building inspector, insurance inspector,
and fire inspector of the use of any extension cord set if required by
local law.
The cord set used to supply power to the press supplies power only to
the press.
The cord set receptacle is a single outlet receptacle. The receptacle of
the extension cord set must be compatible with the press plug (no
adapters permitted).
The cord set is of proper amp voltage to carry the load over the
distance/length needed. Length is not to exceed 25 feet/7.62 meters.
Cord conductors shall be a minimum of AWG# 12 (16.1 to 20.0 amps),
AWG # 14 for (12.1 to 16.0 amps), and AWG # 16 (7.1 to 12.0 amps) for
25 foot/7.62 meter lengths.
The cord set has UL or CSA listing or both, and shall have appropriate
markings or labels such as type (S, SO, ST, SJ, SJO, SJT for 20 amp
capacity or less).
The Plug and Connector are grounded and the polarity and continuity
are checked prior to placing the cord set in service.
The cord set does not cross any aisles or walkways that are required
exits.
Where the Authority Having Jurisdiction permits the use of extruded
cord protectors, in a aisle or walk way, only extruded cord protectors
shall be permitted as protection for the cord set. Cord sets shall not be
run under carpet, through walls, floors, windows or doorways, or
overhead in ceiling plenum space.
The plug of the extension cord set must be compatible with the
receptacle of the wall outlet (no adapters permitted).
The cord set must be a continuous length without splices or in line
switches.
Other Installation Considerations
Other Installation Considerations for the Press
Physical delivery of the press and print server will be by a Xerox
authorized Carrier. The carrier will install and perform a functional check
of the press. The carrier will review the software/documentation with the
customer. For the press the customer is responsible for connecting and
configuring the equipment on their network.
There should be a minimum of 78 inches (1981 mm) clearance from the
floor to the nearest overhead obstruction.
Other Installation Considerations for the Print Servers
One network drop is required for installation of the print server.
The customer is responsible for configuring the print server to the
network.
To enable system administrators and others to work at the print server,
the work surface should be desk height.
Xerox Confidential
Xerox
Versant™ 2100 Press
®
37