Xerox 2300 제품 안전 데이터 시트 - 페이지 2

{카테고리_이름} Xerox 2300에 대한 제품 안전 데이터 시트을 온라인으로 검색하거나 PDF를 다운로드하세요. Xerox 2300 2 페이지.

PRODUCT: 2300
Section V - Emission/Exposure Information*
Light Source
Long term viewing of exposure lamp may be uncomfortable but not harmful.
Electromagnetic Emissions
US
Canada
Germany
Audible Noise
Running:
Standby:
Impulse:
Ozone
92 ug/min
0.009 ppm (TWA)
0.024 ppm (Peak)
Concentration Based on Customer Simulation Model:
Daily Copy Volume
Room Size
1/2 Air Room Change per Hour
Dust
0.024 - 0.31 mg/m
Selenium
< 0.035 - 0.05 ug/m
Arsenic
< 0.022 ug/m
Nitrogen Dioxide
< 0.04 ppm
* TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of
Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are
considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a normal
eight hour workday.
All measurements were made on products performing within established operating specifications and received
recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for
safety and emissions.
FCC: Class A
DOC: Class A
VDE: Class B
59.5 dB (A)
46.5 dB (A)
74.0 dB (A)
270 copies / 7.84 hours
5.0 m
3
3
3
http://www.xerox.com:80/environment.html
3
PSDS No. 0607
TLV
85.0 dB (A)
TLV
0.1 ppm
TLV
3
10 mg/m
TLV
3
200 ug/m
PEL
3
10 ug/m
TLV
3 ppm
07/07/97