Installation – Mobile Home
Warning:
Under no circumstances is this heater to be installed in a makeshift or "temporary" manner.
It may be fi red only after the following conditions have been met.
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE.
•
DO NOT INSTALL IN A SLEEPING ROOM.
Outside air supply must be used for Mobile Home installations (see Figure #4, Page 9.)
We recommend that our woodburning hearth products be installed and serviced by
professionals who are certifi ed in the U.S. by the National Fireplace Institute
NFI woodburning Specialists or who are certifi ed in Canada by Wood Energy Technical
Training (WETT).
Clearances – Mobile Home
This heater must be installed with listed double-wall connector and compatible chimney
system listed on page 10.
Clearances to combustible surfaces and materials are shown below in Figures #3.
Clearances may be reduced with various heat insulating materials. Consult local fi re
codes and authorities for approval.
NOTE: Longer chimney lengths and different pitch fl ashings may be used. All other parts
listed must be installed (see Figure #4, Page 9). Install all components to the connector
or chimney manufacturer's installation requirements. Consult your chimney supplier for
installation advice.
Fig #3
Minimum Clearances to Combustibles – Mobile Home
18"
DOUBLE WALL CONNECTOR
8"
16"
28"
®
(NFI) as
8"
8
CAUTION:
The structural integrity of the mobile
home fl oor, wall, and ceiling/roof
must be maintained.
8"
22"
020512-20 ALT5