Wall Mounting Enclosure (continued)
STEP 3: MOUNT ENCLOSURE
Determine the mounting location for the VersAlarm™ I/O. Hold
the VersAlarm™ I/O up to the desired mounting location, mark
the drill hole locations. Once marked, drill pilot holes for screws
(not included) and use wall mount anchors (not included) if nec-
essary. Place enclosure in the mounting location, adjust until
the pilot holes are lined up with the enclosure and fasten screws
to secure the alarm panel in place.

Wiring

STEP 1: WIRING
The wiring diagram shows six terminals on the terminal block
that consists of three pairs of connections.
1) Starting from the right, the first pair of terminals (5 and
6) are for the power mains. The first line connection (L1)
is installed in terminal 5 and second line connection (L2)
is installed in terminal 6.
2) The second pair of terminals (3 and 4) are for the sensor
connections. The sensor is typically a float switch, but
most digital switch sensors will work with the sensor
input.
3) The third pair of terminals (1 and 2) are for the auxiliary
contacts. This connection can be used on most digital
peripheral alarm monitors or extensions.
4) NEVER leave ground wire exposed inside the panel, use
provided Wago connector for ground termination. See
step 2 for installing wire into Wago connector.
VersAlarm™ I/O - USER GUIDE
Alderon Industries™ - Leading Edge Control Products | 7
AUX
SENSOR
POWER
1 2 3 4 5 6
WAGO