eControls C365T11 설치 프로그램 및 사용자 설명서 - 페이지 2

{카테고리_이름} eControls C365T11에 대한 설치 프로그램 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. eControls C365T11 13 페이지.
eControls C365T11에 대해서도 마찬가지입니다: 사용자 설명서 (4 페이지), 설치 프로그램 및 사용자 설명서 (13 페이지)

Replacing Thermostat Document installer options if
settings are different than factory defaults.
After installing and wiring dampers and sensors to the
thermostat, CHECK FOR ERROR MESSAGES (p.4)
Set time of day (p.4)
Set Options 1-5 (p.5-7) for equipment operation
if different than Factory Settings.
Disabling Airflow Control Turn Airflow Control Off
using Option 15. The thermostat will control the system
just like any other thermostat. Dampers fully open,
nighttime airflow options are disabled and airflow is no
longer displayed on the thermostat
AND COMPLETELY BEFORE PROCEEDING WITH INSTALLATION.
!
Turn off all power to the HVAC system before wiring or installing Comfort365 components.
SEPARATE THE C365 SUBBASE
Place a slotted screwdiriver in the slots as shown and rotate to
remove subbase from the C365 housing.
ATTACH THE SUBBASE TO THE WALL
Attach the subbase to an interior wall and about 5-feet above
the floor as shown using the screws and wall anchors supplied.
The wires to the dampers, HVAC equipment and the
temperature sensor pass through the opening between the
terminals.

ATTENTION INSTALLER

READ THESE INSTRUCTIONS CAREFULLY
R
C
W
Y
C O M
G
C L S
N C
O P N
T S
C O M
C L S
O P N
T S
USER Airflow Control enables the user to control the
airflow rather than the thermostat automatically
controlling the airflow. Installer must enable Option 16
and the user must turn off automatic airflow in the
User Options. Nighttime Airflow Control is still enabled,
but can be turned off using the User Options.
Nighttime Airflow Control is defaulted to On. If
bedrooms are located downstairs, consider turning off the
Nighttime Airflow Control option using the User Options.
Go to www.eControlsUSA.com/contractor for installer
resources.
INSTALL TWO AA BATTERIES
The batteries power the clock
when 24VAC power is lost.
Slide the battery cover
downward and install the two
AA batteries as shown.
INSTALL SLEEPING AND LIVING AREA DAMPERS
Install an R80CT damper in the duct supplying air to the
sleeping area and wire the terminals to the corresponding
terminals on the C365T11. Install a second R80CT damper in
the duct supplying air to the living area and wire it to the
C365T11. Each damper uses 2.4VA of power.
Ensure that damper installation does not cause
obstruction to the damper blade.
When two or more dampers are required to define the sleeping
or living area, the dampers may be wired in parallel. LEDS on
the damper actuator indicate when the damper is fully open
(green) or fully closed (red).
2
Green LED
Red LED