VertiMAC™ Pump Switch - USER GUIDE
Additional Assembly and Product Information
This VertiMAC™ pump switch model comes pre-assembled with the actuator rod, float, and pipe clamp bracket installed. The
pumping differential is set at the maximum range (6.0"). If adjustments or servicing is required, use this section for additional
instructions on the VertiMAC™ pump switch.
MOUNTING PIPE CLAMP BRACKET
Place the pipe clamp bracket on the bottom of the VertiMAC™
pump switch housing and line up the holes. Use a #2 phillips
head screwdriver to securely fasten the bracket to the housing
with provided screws.
INSERTING ACTUATOR ROD
Slide the actuator rod arm upward into the front of the VertiMAC™
pump switch housing, positioned so the notch on the actuator arm
matches the side of the housing with the hole. If the actuator rod
arm is inserted in the correct position, the pump switch housing
should make a clicking sound as the rod slides up and down.
ACTUATOR PIN PLACEMENT
Once the actuator rod arm has been placed into the VertiMAC™
pump switch housing in the up position, insert the actuator pin
into the small hole on the left side of the housing until it snaps
in place.