Overriding Automatic Airflow
In AUTOMATIC AIRFLOW MODE, the user can override the airflow to
the upstairs and downstairs by pressing AIRFLOW % in the area
shown and then use the UP/DOWN keys to adjust the airflow. After 3
hours, the thermostat returns to automatic operation. UPSTAIRS,
AIRFLOW% and DOWNSTAIRS blink when in airflow override.
Upstairs
Airflow %
Auto
Hold
Downstairs
Inside
Eve
We
SYSTEM
PM
MENU
MODE
This area will blink when
in airflow override.
Terminating Airflow Override
AIRFLOW OVERRIDE can terminated by pressing
area shown and then pressing the Mode key. The thermostat returns
to automatic airflow control. The AIRFLOW % returns to the airflow
prior to the override.
Upstairs
Airflow %
Hold
Downstairs
Inside
Eve
We
SYSTEM
PM
MENU
MODE
User Options
Set Schedule
Selecting Manual or Auto Airflow
Turning Nighttime Airflow Option On or Off
Setting Nighttime Airflow in Heating
Setting Nighttime Airflow in Cooling
Cleaning the Touchscreen
Turning WiFi On or Off
Linking WiFi Thermostat
Factory Set Schedule
The thermostat comes pre-set with the following energy-saving
schedule for weekdays (Monday-Friday) and weekends
(Saturday-Sunday).Using these settings can reduce your
heating/cooling expenses.
Monday through Friday
Morn
Day
Even
Nite
Saturday and Sunday
Morn
Day
Even
Nite
Touch AIRFLOW% as shown.
Touch the UP key to increase the
upstairs airflow (the downstairs airflow
will automatically decrease). Touch the
COOL
DOWN key to increase downstairs airflow
(the upstairs airflow will automatically
AUTO
decrease).
FAN
The override range is defined by the
installer during set up.
AIRFLOW %
Touch AIRFLOW% as shown.
Touch the MODE key to terminate airflow
override.
COOL
The thermostat returns to automatic
airflow control. The AIRFLOW % returns
AUTO
to the airflow prior to the override.
FAN
Time
Heat
6:00 AM
70
8:00 AM
62
6:00 PM
70
10:00 PM
62
Time
Heat
6:00 AM
70
8:00 AM
62
6:00 PM
70
10:00 PM
62
Change Factory Set Schedule
Touch the
MENU
the weekday or weekend schedule to display or change.
Mo
Tu
We
ThFr
MENU
Morn
Mo
Tu
We
ThFr
AM
in the
MENU
Morn
Mo
Tu
We
ThFr
AM
MENU
Morn
Mo
Tu
We
ThFr
AM
MENU
Continue setting the start times, heating setpoints, cooling setpoints for
the Day, Evening and Night schedules.
Touch ENTER to save the schedules to the weekdays or the weekend.
Selecting Manual or Auto Airflow
This option is only displayed if your installer enabled Manual Airflow
Control during installation. AUTOMATIC AIRFLOW is the default. In
AUTOMATIC AIRFLOW CONTROL, the airflow is adjusted by the
thermostat. In MANUAL AIRFLOW CONTROL, the user must adjust
the airflow. The airflow range is defined by the installer during set up.
Cool
75
Upstairs
83
Airflow %
75
Auto
Downstairs
78
Cool
75
MENU
83
75
78
6
key to display SCHEDULE. Here you will select either
SELECTING THE WEEKDAY OR
WEEKEND SCHEDULE
Touch the UP key to select the weekday
Schedule
schedule (MoTuWeThFr) or touch the
DOWN key to select the weekend
schedule (SaSu) and then touch NEXT.
NEXT
ENTER
SETTING THE MORNING SCHEDULE
START TIME.
Touch the UP/DOWN keys to change the
Schedule
Morning Schedule Start Time and then
touch NEXT.
NEXT
ENTER
SETTING THE MORNING SCHEDULE
HEATING TEMPERATURE.
Heat
Set To
Touch the UP/DOWN keys to change the
Schedule
Morning Schedule Heating Setpoint and
then touch NEXT.
NEXT
ENTER
SETTING THE MORNING SCHEDULE
COOLING TEMPERATURE.
Cool
Set To
Touch the UP/DOWN keys to change
Schedule
Morning Schedule Cooling Setpoint and
then touch NEXT.
NEXT
ENTER
Touch the MENU key until the following
thermostat screen is displayed.
Touch the UP key to select AUTO. Touch
the DOWN key to select MANUAL.
Touch the
MENU
NEXT
ENTER
next option or touch the ENTER key to
save the options.
key to save and go to