Alderon Industries Mini Power Post PRPT-00003 빠른 시작 매뉴얼 - 페이지 2

{카테고리_이름} Alderon Industries Mini Power Post PRPT-00003에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alderon Industries Mini Power Post PRPT-00003 2 페이지. Pump connection center
Alderon Industries Mini Power Post PRPT-00003에 대해서도 마찬가지입니다: 사용자 설명서 (16 페이지)

Alderon Industries Mini Power Post PRPT-00003 빠른 시작 매뉴얼
Step 5: Install Bottom Cover
Line up the bottom enclosure cover with the grooves (5A), then slide
directly upward (5B) until it meets the top of the enclosure so the screw
hole is lined up and replace the screw at the bottom of enclosure.
5A
Step 6: Power System, Test and Backfill
After all wiring and installation steps have been completed, power the system
with incoming voltage(s) to match the pump and alarm voltages. Use the fea-
tures list and diagram below to perform a quick test of the system to make sure
it is working properly. Note: For the complete wiring, installation instructions,
or troubleshooting, refer to the user guide for this model by scanning QR code.
Backfill Area:
Once all steps of the installation are finished
and testing is complete, backfill the area you
dug for the post and riser in step 1.
2
3
SMP172B2
1
2 3
4
5B
Backfill
Area
Backfill
Area
Mini Power Post
Model Number Nomenclature
1
Base Model (Mini Power Post™ Standard)
2
Pump Voltage (120VAC Pump)
5
Included with Product
▪ (1) Mini Power Post™; junction box pre-installed on post
▪ (1) Pre-installed, female, 15A pump power receptacle
(120VAC or 230VAC depending on part number)
▪ (4) Pre-installed cable grips
▪ (1) Junction box partition
▪ (5) Wago connectors; three pre-installed and two additional
Customer Support
Online
alderonind.com
Email
QR Code
Scan code for full product details
Specifications
Pump Power Receptacle: 120VAC or 230VAC, 15A, 60Hz
Pump Power:
Enclosure:
Certifications:
- Features
1
Vented Post Cap - Allows airflow to prevent gases/condensation inside post
2
Junction Box Enclosure - Pre-installed on post for easy wiring installation
3
Cable Grips - Pre-installed for easy installation
4
Partition - Separates high voltage from low voltage
1
Pump Power Receptacle (not shown) - Pre-installed, female, 15A
5
(120VAC or 230VAC depending on part number)
6
Post - Provides wire routing access and protection from water intrusion
7
QR Code (not shown) - Scan code for additional product information (alderonind.com)
3
4
6
Alarm Options
(1-Zone Indoor Alarm, 15' Alarm
3
Float, and 15' Filter Switch)
4
Pump Switch Options (15A, 15' Wide Angle)
(voltage depends on model/part number)
120VAC or 230VAC, 13A or 15A, 60Hz
(voltage/amps depends on model/part number)
Outdoor, rated Type 3R
CSA (US and Canada)
5
Riser Kit/Access Options (2.5" Riser Connection Kit)