eControls Comfort365 C365T11 설치 프로그램 및 사용자 설명서 - 페이지 8
{카테고리_이름} eControls Comfort365 C365T11에 대한 설치 프로그램 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. eControls Comfort365 C365T11 13 페이지.
eControls Comfort365 C365T11에 대해서도 마찬가지입니다: 사용자 설명서 (4 페이지), 설치 프로그램 및 사용자 설명서 (13 페이지), 사용자 설명서 (4 페이지), 설치 프로그램 및 사용자 설명서 (13 페이지), 설치 프로그램 및 사용자 설명서 (13 페이지), 설치 (2 페이지)
18 User (Manual) Airflow Control
Enabled
Factory Default: On. Range: On or Off.
Manual airflow control enables the homeowner
to direct more airflow to the living or sleeping
space as they desire. This option is ideal for
homeowners who have an unusual work
schedule, home office or spend more time in one
space than the other. The User Menu is used to
turn off automatic airflow control. Nighttime
Airflow option is still enabled but can be turned
off using the User Options.
Use the
DOWN
key
Option
to select OFF only if
disabling manual
airflow control. (Not
typical)
Touch NEXT or ENTER.
19 Upstaging Time
Factory Default: 10 min. Range: 5 to 30 min.
Use the
UP/DOWN
Option
keys to set the time at
which second stage
heating or cooling is
activated.
Touch NEXT or ENTER.
For options 20 - 23, use the installer test
o
n the following page to determine the
max
imum allowable airflow.
20 Maximum Airflow in Heating
to the Sleeping Area
Factory Default: 160%. Range: 100% to 160%.
Use the
UP/DOWN
Sleeping
Option
keys to select the
Airflow %
maximum allowable
airflow in heating to
the sleeping area.
Touch NEXT or ENTER.
21 Maximum Airflow in Cooling
to the Sleeping Area
Factory Default: 150%. Range: 100% to 160%.
Use the
UP/DOWN
Sleeping
Option
keys to select the
Airflow %
maximum allowable
airflow in cooling to
the sleeping area.
Touch NEXT or ENTER.
INSTALLER SECTION
22 Maximum Airflow in Heating
to the Living Area
Factory Default: 160%. Range: 100% to 160%.
Use the
UP/DOWN
keys to select the
maximum allowable
airflow in heating to
the living area.
Touch NEXT or ENTER.
23 Maximum Airflow in Cooling
to the Living Area
Factory Default: 150%. Range: 100% to 160%.
Use the
UP/DOWN
keys to select the
maximum allowable
NEXT
ENTER
airflow in cooling to
the living area.
Touch NEXT or ENTER.
24 Maximum Temperature
Differential
Factory Default: 2 F.
This is the maximum allowable temperature
difference between the sleeping and living area
NEXT
ENTER
temperatures. When the temperature difference is
equal to or greater than the allowed differential,
the airflow is adjusted.
Use the
UP/DOWN
keys to select the
maximum allowable
temperature
difference between
the sleeping and
living area.
Touch NEXT or ENTER.
Heat
25 Factory Restore
WARNING! Factory Restore resets ALL settings.
NEXT
ENTER
To exit this option,
touch
NEXT
or
ENTER, or the hidden
Back key.
To restore factory
settings, touch the
Cool
UP
key to display
YES then touch
ENTER.
NEXT
ENTER
Option
Heat
Airflow %
Living
NEXT
ENTER
Option
Airflow %
Cool
Living
NEXT
ENTER
o
o
o
Range: 0 to 10 F
Option
NEXT
ENTER
Option
NEXT
ENTER
Option
NEXT
ENTER
Page 8 of 12