operated through a router, enter the address of the router on the gateway field, otherwise leave this
field blanc. Be sure, that the 'DHCP' mark is unchecked. Finally click to the 'Yes' button to set the
new parameters at the power sensor
Now the IP configuration of the power sensor is completed. You may finally want to test if the power sensor
is reachable now. Start your web browser and type the power sensor's IP address into the URL field of the
browser. The power sensor should reply with it's main page, provided that the power sensor and your
computer are configured for the same subnet.
2.3 Connecting the Power Sensor
The connectors of the power sensor are placed on both sides. One side contains the RF input connector, the
other side the D/C and Data connectors.
RF connectors
The RF input connector is a make N-type connector, mounted at one front panel of the power sensor
enclosure. At the other side, the Ethernet and power supply connectors are mounted. The Ethernet
connector is a standard 10 Base-T / RJ45 connector. Use a standard network cable to connect the power
sensor to an Ethernet hub. If you want to connect your computer and the power sensor directly without
using a hub, you need a crossover cable for this with swapped RX/TX lines.
The power supply connector also contains the fault relay contact. The latter is a floating Photo MOS solid
state circuit. In fault state (level below an adjustable threshold) or while the unit is powered off it is in hi-Z
state (several MOhms). A resistance below 10 Ohms indicates that the function is OK. The diagram below
shows the pin out of this connector (front view).