DirectConnect DCRACK38U 사용자 설명서 - 페이지 3

{카테고리_이름} DirectConnect DCRACK38U에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DirectConnect DCRACK38U 4 페이지. Professional series racks complete rack with casters, power strip, thermal control and dual fans

2.0 F
EATURES
This high-performance DirectConnect
benefits and features that enable it to perform in a superior manner. Among those
benefits and features you will find:
Quick and easy to assemble design allows for flat shipment
1U Digital Thermal Controller
(LCD display menu)
1U 6 outlet Power Distribution Strip with protected on/off switch and long ground power cord
Adjustable numbered 2.5mm
(11gauge)
mounting rails to fit virtually any piece of 19" equipment.
Robust locking
six screw heavy duty caster system
(2)
Four adjustable
(one in each corner of base)
Removable Cable Knockouts on rack's top and bottom
Heavy-gauge steel tops & bottoms, seamless steel sides, and rails
Locking, removable, & reversible custom designed tempered glass front door
Locking, removable, & reversible vented rear door
Heavy duty and durable black textured powder coat finish
Cable channel molding option between rails and doors for 2" x 2" PVC" cable management
19" equipment width rail size for the 29U, 38U, and 42U racks
29U Rack Dimensions:
57.5" x 23.75" x 23.75"
(H x W x D)
38U Rack Dimensions:
70.86" x 23.75" x 23.75"
(H x W x D)
42U Rack Dimensions:
78.75" x 23.75" x 23.75"
(H x W x D)
3.0 P
C
ACKAGE
ONTENTS
Before attempting to use these DirectConnect
packaging and make sure the following items are contained in the shipping carton:
Front, back, and two (2) side assemblies
Two (2) left and two (2) right mounting rails
1U digital thermal controller
1U 6 outlet power distribution strip
Adjustable locking feet – four (4)
DirectConnect
User's Manual
®
42 - M5x10mm bolts
for assembly
38 – 10-32 bolts
for mounting rails
Note: Please retain the original packing material in case you need to return the unit. If you
find any items missing, contact DirectConnect
the model number, serial number, and invoice available for reference when you call.
MPORTANT: For optimum performance and safety, please read these instructions carefully before
I
assembling, operating, or adjusting this product. Please keep this manual for future reference. If you
don't understand correct installation instructions, please consult your regular installation specialist
*DirectConnect
Professional Series Racks have many
®
and top loaded dual 5" Cooling Fans
heavy duty threaded
and square knockout
(2)
heavy duty locking feet
(1,460.5 x 603.3 x 603.3mm)
(1,860.5 x 603.3 x 603.3mm)
(2,057.4 x 603.3 x 603.3mm)
Professional Series Racks, please check the
®
(Total of 3 cartons)
Top assembly with dual fans
Base assembly
Four (4) base cable plates
Power cord for PDU strip
Four (4) locking casters
Keys –two (2) sets of two (2)
42 - M6x12mm bolts
for assembly
immediately (800.531.3224). Please have
®
®
is a registered trademark.
4 / 8
These DirectConnect
C
:
AUTION
the maximum weights indicated. See apparatus instructions. Use with products heavier
than the maximum weights indicated may result in instability, causing possible injury.
Step 1: Unpacking Carton 2 of 3,
(2)
Installing Left
and Right
(A)
square knockout mounting rails on Left and Right Side Assembly
Using M6x12 screws
(G)
left
and right
mounting rails as shown in Figure 1.
(A)
(B)
Step 2: Unpacking Carton 1 of 3
Using eight
M6x12 screws
(8)
1 of 3 and attach to the Left
Installing the Back Assembly (2) to Left (3), Right (3), & Front (1) Assemblies
Fig.2
4.0 I
G
NSTALLATION
UIDE
We are not responsible for any personal injury or product
damage due to mishandling, incorrect mounting,
incorrect assembly, or incorrect use of this product
Professional Series Racks are intended only with
®
removing transit parts, and side assemblies.
(Two
Side Assemblies, Left
(2)
Remove the small mini shipping screws
opposite of side door releases on both the
left & right side of side rack assembly
remove side panels to start rack assembly.
threaded mounting rails or Left
(B)
and M6 snap nuts
(I)
(six (6) per rail)
(six (6) per rail)
and assembly Front & Rear Assembly to sides.
attach the Front Assembly
as unpacked from carton
(G)
(1)
and Right
assemblies as shown in Figure 2.
(A or J)
(B or K)
Using eight
M6x12
(8)
screws (G) attach the
Back Assembly (2)
as unpacked from
carton 1 of 3 and
attach to the left and
right assemblies (3)
as shown in Figure 3.
I
: Do not
MPORTANT
force the bolt into
the hole, which may
damage equipment
and injure of person.
5/ 8
& Right
Mounting Rails)
(2)
(2)
(2)
to
(3)
and Right
(J)
(K)
attach the
Fig.3