Yamaha BBT 500H 소유자 매뉴얼 - 페이지 14
{카테고리_이름} Yamaha BBT 500H에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Yamaha BBT 500H 21 페이지. Yamaha bass amplifier owner's manual
Yamaha BBT 500H에 대해서도 마찬가지입니다: 사전 설정 패치 목록 (1 페이지), (네덜란드어) 매뉴얼 (21 페이지)
![Yamaha BBT 500H 소유자 매뉴얼](/uploads/products/server2/7072370/7072370.png)
Detailed Parameter Settings
Utility Mode
The Utility Mode provides settings for the Crossover Filter and MIDI.
These settings are saved internally when you exit the Utility Mode and
kept even when the amplifier's power is switched OFF.
Entering the Utility Mode
To enter the Utility Mode, from any mode press and hold the [FUNC-
TION] switch for more than 3 seconds, until "
play.
How Knobs Function in the Utility Mode
In the Utility Mode, only the INPUT LEVEL, OUTPUT, and COMP knobs
function. All other knobs (SOUND TYPE, GAIN - TREBLE) have no func-
tion.
• INPUT LEVEL: Sets the Input Level
• OUTPUT: Sets the output level
• COMP: Sets the cut off frequency of the crossover filter
When the COMP knob is used (when setting the crossover filter), the
setting's value is shown in the display. Other than that, only
pears on the display.
Use the [MANUAL] switch and Memory Switches [1] through [5] to set
individual MIDI settings. (
When the COMP knob is used (when
setting the crossover filter), the setting's
Individual MIDI
value is shown in the display. Other than
Settings
that, only
q
14
utL
" appears on the dis-
[MIDI Settings] pg. 15)
utL
appears on the display.
w
By connecting two BBT500Hs as shown in the illustration below, you
can create a bi-amplified system, where one amplifier is used to drive
high frequencies and a second amplifier drives low. This system uses
the amplifier's onboard crossover filter (LPF or HPF) to determine the
range of frequencies that each amplifier will deliver.
Setting the Crossover Filter
1
Press and hold the [FUNCTION] switch for more than three sec-
onds (until "utL" appears on the display) to enter the Utility
Mode.
2
Rotate the COMP knob to set the Crossover filter's cutoff fre-
quency.
* Range of cutoff frequency
L10
(LPF 100Hz) to
h10
(HPF 100Hz) to
When using a bi-amplified system, make sure
that the INPUT LEVEL control knob on the
second BBT500H is set to its minimum level.
Ex.) Operating a bi-amplified system in which the crossover fil-
ter on the first amplifier is set to h50 (HPF 500Hz) to pro-
duce high frequencies, and the crossover filter on the sec-
ond amplifier is set to L50 (LPF 500Hz) to produce low fre-
quencies.
First amplifier (HPF 500Hz)
utL
ap-
INPUT
Second amplifier (LPF500Hz)
INPUT
e
* Set the INPUT LEVEL
to its minimum level
Crossover Filter
L00
byP
(LPF 1000Hz),
h00
(HPF 1000Hz), 93 steps
TUNER
OUT
Bass
h50
* Set to "
" with
the COMP control
knob
L50
* Set to "
" with the
COMP control knob
(Bypass),
SPEAKER
Produces
higher
frequencies
above 500Hz
SPEAKER
Produces
low
frequencies
up to 500Hz