Yamaha CP2000 서비스 매뉴얼 - 페이지 18

{카테고리_이름} Yamaha CP2000에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Yamaha CP2000 33 페이지. Yamaha power amplifier owner's manual
Yamaha CP2000에 대해서도 마찬가지입니다: 소유자 매뉴얼 (20 페이지), 서비스 매뉴얼 (33 페이지)

Yamaha CP2000 서비스 매뉴얼
CP2000
1.2.10 Stability
The following conditions shall be met when a 10 kHz, -10dBu rectangular pulse is input and a capacitance of 10 pf ~ 0.47 F is
connected in parallel with a load resistance of 4 .
Overshoot Vp/Vo
Ringing: Within 5 waves
Next, when there is only a pure capacitance of 10 pf ~ 0.47 F the following conditions shall be met.
< =
Vp/Vo
2.5
Ringing: There shall be convergence within 7 waves and no oscillation, etc.
1.2.11 Protection circuit
The protection circuit shall operate and the relay shall not open when a 10 Hz, +5.4 dBu sine wave is input and the output wave is
made to clip. Next, the protection circuit shall operate within two seconds and break the output when a 1 Hz, 0.0 dBu sine wave is
input. In addition, when the input signal is cut, it shall automatically recover within 10 seconds.
1.2.12 Efficiency
(1) The primary electrical power shall be measured and be within the range shown below when a 1 kHz, -6.6 dBu sine wave is input
to the input terminal.
330 W
50 W (U: 4.0 A
(2) The primary electrical power shall be measured and be within the range shown below when the input terminal is grounded by the
introduction of the input terminal.
25 W
10 W
1.2.13 PC limiter and comp
Input a 1 kHz, -1.5 dBu sine wave to the input terminal and connect 1
< =
< =
a 10 V
Vrms
16 V sine wave shall be attained at the output. The total harmonic distortion ratio shall be THD=5 % or less.
Also at this time, the clip indicator shall come on. This inspection shall be completed within 30 seconds.
1.2.14 Signal indicator
The green signal indicator shall come on when a 1 kHz, -23 dBu sine wave is input.
In addition, the green and yellow signal indicators shall come on when a 1 kHz, -4 dBu sine wave is input.
2.

Bridge mode

2.1
Preparations
Input attenuator
Input terminal
Mode SW
Yamaha speaker processing
Output terminal
Load resistance
Measurement connection
2.2
Inspection
2.2.1 Gain
An output voltage of +24.0
18
< =
1.8
0.6 A,
H: 2.0 A
(U: 0.33 A
0.13 A, H: 0.20 A
L channel only operates. Set to MAX.
L channel cannon connector (No. 2 hot, No. 1, 3 ground)
Bridge
Off
Use L channel +, R channel +.
4
+ 4 , Non inductance resistor, input capacitance 500 W or more.
Set to a floating ground and connect at center point of load resistance.
SPEAKERS
1.0 dBu shall be attained when a 1 kHz, -10 dBu sine wave is input to the input terminal.
0.3A)
0.08 A)
( 5 %) as a load to the output terminal. Under these conditions,
MEASURING
INSTRUMENT
INPUT
GND