4.INSTALLATION INSTRUCTION
6). The air inlet and outlet are at the top side, main unit should not place at an open air.
Avoid the rain to enter the vents.
The air inlet and outlet can connect the φ150 air duct for air ventilation, see below pic.
STATUS: Heating
Outlet water temp. 31℃
Target temp.
57℃
24/06/2011
09:28
(Fig.1)

5.TRIAL RUNNING

Trial Running
1). Check if the heat pump is placed in a well ventilated and installed in a dry
place.
2). Check if the water tank is full of water, and open the water outlet tap till
water flows out.
3). Make sure the water pressure is normal (0.1Mpa ~0.7 Mpa).
4). Check the power supply is normal or not, (voltage range 220v +-10 %)
5). Check if all the equipped parts are well secured and well connected.
6). A suitable circuit breaker must be connected.
7). Check whether the condensation and drain pipe are connected well.
8). After power is switched on, check if the LCD controller displays normally.