aerauliqa Quasar N 설치 매뉴얼 - 페이지 4
{카테고리_이름} aerauliqa Quasar N에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. aerauliqa Quasar N 20 페이지. Mixed-flow fan
aerauliqa Quasar N에 대해서도 마찬가지입니다: 설치 매뉴얼 (20 페이지)
• Turn off the main switch whenever a malfunction is detected or when cleaning.
• For installation an omnipolar switch should be incorporated in the fi xed wiring, in accordance with the wiring regulations, to provide a full
disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a
hazard.
• Do not obstruct the fan or exhaust grille to ensure optimum air passage.
• Ensure adequate air return into the room in compliance with existing regulations in order to ensure proper device operation.
• If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that is not a "sealed
chamber" type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation.
• Install the product so that the impeller is not accessible from the air outlet side as verifi ed by contact with the Test Finger (test probe "B" of the
norm EN61032) in compliance with the current safety regulations.
VERSIONS
Quasar N
Equipped with high quality sleeve bearing motor.
BB version (on request): motor mounted on ball bearings that guarantee a longer product life cycle (30,000 h) and suitable for cold climates.
Single speed operation.
Wiring diagram fi g.15A
Quasar T
Equipped with high quality sleeve bearing motor.
BB version (on request): motor mounted on ball bearings that guarantee a longer product life cycle (30,000 h) and suitable for cold climates.
Single speed operation.
The fan is provided with a timer circuit which is adjustable from aprox. 1 minute to 25 minutes via trimmer (fi g. 16B).
Operation: connected according to the diagram in fi gure 15B, after the light is switched on, the fan activates with a delay of max 1.5 seconds.
After the light is switched off, the fan continues to function for a pre-set period of time.
QUASAR 2S BB
Equipped with enhanced high performance motor mounted on ball bearings to assure a longer fan life (30.000h). Ideal for cold climates.
Two speed operation. The speed can be selected during the installation by positioning the jumper as per fi g.17A-17B.
Wiring diagram fi g.15C
STANDARD CONFORMITY
2014/35/EU Low Voltage Directive (LVD)
2014/30/EU Electromagnetic Compatibility (EMC),
in conformity with the following standards:
Electrical Safety
EN60335-1(2008); EN 60335-2-80(2005); EN 60335-2-80/A2(2009)
Electromagnetic Compatibility
EN 55014-1(2006)+A1+A2; EN 55014-2(1997)+A1(2001)+A2(2008)+IS1(2007)
EN 61000-3-2(2006)+A1(2009)+A2(2009); EN 61000-3-3(2008).
4