1) Open the cover of the connection enclosure. Insert the DC Line wires into the housing and connect to the
terminal block note the polarity of the wire. The terminal block has been label with V + and GND to aid
installation. The DC output is pre-wired to the light bar. If this connection is removed during installation,
reconnect the white wire to V+ and green wire to GND. Failure to do so could result in permanent damage
to the power supply. Terminal torque value 4.5 LBF-IN (0.5 N m) Wire size of #12-20 awg (2.05-.81mm)
input and Maximum of wire size of #18 awg (1.02 mm) output. See figure 2.
2) The cable length from the remote mount enclosure to the LED illuminator is 8 foot. Wire length from the
power supply and zener diode barrier to the remote mount enclosure is up to 1800 feet (548 Meters) using 2
strand #18 wire AWG (1.02 mm). Longer distances available depending on wire choice. See specifications
on page 3.
3) Replace the cover on the power supply housing.
4) Switch "ON" the power supply making sure the Illuminator is functioning properly, with all LED's
illuminated.
5) Refer to the troubleshooting section in this manual if a portion or all of the LEDs do not illuminate.
1) Disassemble the field-wireable connector. See figure 3.
16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828
Led Illuminator with Connection enclosure
Figure 2: Enclosure
Led Illuminator with Field-Wireable Connector
Figure 3: Field Wireable Connector