Clark-Reliance Jerguson LumaStar EPL-316 설치, 운영 및 유지보수 지침 매뉴얼 - 페이지 9

{카테고리_이름} Clark-Reliance Jerguson LumaStar EPL-316에 대한 설치, 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clark-Reliance Jerguson LumaStar EPL-316 12 페이지.
Clark-Reliance Jerguson LumaStar EPL-316에 대해서도 마찬가지입니다: 설치, 운영 및 유지보수 지침 매뉴얼 (12 페이지)

Clark-Reliance Jerguson LumaStar EPL-316 설치, 운영 및 유지보수 지침 매뉴얼
REFLEX BRACKET STYLE
*NOTE: Illuminator pictured is model EPL-100. Model EPL-316 mounts in the same manner except the power supply is
always remote mounted. Identify your bracket type. Confirm the bracket style matches that in the below pictures. If the
bracket received is different than shown here and on page 2, contact factory for assistance.
NOTE: installation onto a Reflex Gauge requires removal of nuts on the gauge. Do not install illuminator with
gauge in service.
1) Install the brackets onto the illuminator leaving the bracket thumb screws loose. The brackets should move freely
up and down in the illuminator channel.
2) Remove top and bottom nuts from the Reflex Gauge on the side of the gauge that the illuminator is to be installed
on.
3) Position brackets onto studs, reinstall gauge nuts and tighten to the torque specified for your gauge.
4) Position illuminator so it is centered on the Reflex Gauge and tighten the bracket thumb screws. The illuminator
should be mounted as shown in Figure 13.
Reflex Bracket Mounting
16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828
Figure 17
www.clark-reliance.com ● [email protected]
8