Clarke 3120500 운영 및 유지 관리 지침 - 페이지 10
{카테고리_이름} Clarke 3120500에 대한 운영 및 유지 관리 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke 3120500 17 페이지. Air ratchet wrench
MAINTENANCE
WARNING: MAKE SURE THAT THE AIR TOOL IS DISCONNECTED FROM THE
COMPRESSED AIR SUPPLY BEFORE STARTING ANY CLEANING OR
MAINTENANCE PROCEDURES.
DAILY
1. Before use, drain water from the compressed air supply.
2. Pour a few drops of Clarke air-line oil, into the tool air inlet. This should be
carried out regardless of whether or not an in-line mini oiler is used. If an in-
line mini oiler is not used, this procedure should be repeated after every
two to three hours of use.
WEEKLY
1. Check the air inlet screen filter for
blockage and clean if necessary.
CLEANING
1. Keep the body of the tool clean
and free from debris.
2. Grit or gum deposits in the tool
may also reduce efficiency. This
condition can be corrected by
cleaning the air strainer and
flushing out the tool with gum solvent oil, or failing this, the tool should be
disassembled, thoroughly cleaned, dried and reassembled. This is better
left to your Clarke dealer.
3. After extensive use, remove the inlet screen filter and flush out the
mechanism with gum solvent oil or an equal mixture of Clarke air-line oil
and paraffin. Allow to dry before use.
4. Clean the air inlet filter screen inside the air inlet.
5. If the tool runs erratically or becomes inefficient, and the air supply is of
good quality, it may be necessary to dismantle the air motor and replace
worn or damaged parts. You may prefer to take the tool to your Clarke
dealer if internal maintenance is required.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
10