5. Replace the filler cap ensuring the O-ring is in place.
NOTE: Place your air compressor in another room to prevent damage
from the intake of abrasive dust laden air.
TO START BLASTING
NOTE: Start with all valves in the closed position. Following the instructions
below will help prevent clogging in the delivery hose, outlet
manifold and in the gun.
1. Connect the compressor to the
inlet connector.
2. Start the compressor and open
the air supply valve, see Fig 11.
• The tank will start to pressurise.
3. Test the safety valve by pulling up
on the valve as shown in Fig 12.
• Air will hiss out when the valve is
pulled.
•
•
•
•
4. Open the throttle valve, Fig 13.
5. Check for leaks at the filler cap
and along all hoses and fittings as
the system pressurises. If leaks are
observed, release the pressure
from the tank and repair any leaks
immediately.
6. Press and hold the trigger until air
is flowing through the gun.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]