HYDRAULIC PUMP/RAM OPERATION

1. Before using the press, purge any
air from the system by opening
the release valve by turning it anti-
clockwise and pumping several
full strokes to eliminate any air
bubbles. Tight the release valve
before continuing.
2. Check all parts are secure and
correctly aligned before using the
press.
The press is now ready for use.

POSITIONING THE BED

1. Position the bed at the desired height, so it will be as close as possible to
the ram when the workpiece is mounted on it.

FITTING THE MANDRELS OR PRESSURE CAP

Mandrels are available as an
adaptor kit, any of which may be
connected to the end of the ram
using the adaptor.
Alternatively, the basic ram pressure
cap can be fitted as shown. Secure
the pressure cap by tightening the
grub screw with a suitable hex key.
If one of the mandrels is required, the
adaptor must be fitted instead of the
pressure cap. Secure the adaptor by
tightening the grub screw with a
suitable hex key.
Select your mandrel depending
upon the size of the workpiece
bearing surface.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]