Instructions for the installer

The instructions given below are
designed specifically for a qualified
installer and should aid him or her to
perform all installation, adjustment,
and maintenance operations with
absolute precision and in compliance
with all current legislation and
regulations. We strongly recommend
that all operations for the installation
of your cooker be carryed out by
Qualified Personnel in accordance
with existing rules and regulations.

Electrical connection

Prior to making the electrical connection,
make sure that:
1. the protection fuse and the domestic wiring
system are suitable to carry the total
electric load of the oven (see rating plate);
2. your domestic wiring system has an efficient
earth connection in compliance with rules
and laws in force;
3. the wall socket or the omnipole switch used
for the electrical connection can easily be
reached after the oven is built in.
This appliance is delivered without an
electric supply cable, therefore, you will
have to fit to it a supply cable with standard
plug, suitable for the total electric load
shown on the rating plate. The plug is to
be inserted into a suitable wall socket. If
you require a direct connection to the
electric network (mains), it will be
necessary to fit between the appliance and
the mains an omnipole switch, with a
minimum gap between contacts of 3 mm,
suitable for the required load and in
compliance with rules in force. The green &
yellow ground wire must not be interrupted
by the switch, and should be 2-3 cm longer
than the phase and neutral wires. The supply
cable must in all cases be laid out in such a
way as to ensure that it does not reach at
16
any given point a temperature 50°C higher
than the ambient temperature.
Suitable power supply cables are the
following types, considering the respective
necessary section of cable: H07 RN-F, H05
RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F
(T90), H05 BB-F.
Connecting the terminal board
The appliance incorporates an easily
accessible 6-pole terminal board whose
jumpers (bridges) are already pre-set for
operation on 400V tri-phase with neutral wire
(Fig.11). In case a different mains voltage is
present, the jumpers on the terminal board
must be rearranged as shown in the diagram
(Fig.12). The ground cable must be
connected to terminal
the supply cable to the terminal board,
secure it with a junction clamp.
Fig. 11
1 2 3 4 5
230V 3~
L1
L2
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1 L2
1 2 3 4 5
400V 3N~
L1 L2 L3 N
. After connecting
Ø 4x2,5mm²
L3 PE
Ø 3x2,5mm²
N
PE
Ø 4x2,5mm²
N
PE
Ø 5x1,5mm²
PE
Fig. 12