Zanussi FJE 904 지침 책자 - 페이지 20

{카테고리_이름} Zanussi FJE 904에 대한 지침 책자을 온라인으로 검색하거나 PDF를 다운로드하세요. Zanussi FJE 904 23 페이지. Washing machine fje 904 - fje 1204g

132992150•FJE904•gb.qxd
02/04/03
• Remove any objects from the pump impeller by
rotating it.
• Put the cap back on the emergency emptying hose
and place the latter back in its seat.
• Screw the pump fully in.
• Close the pump door.

Water inlet filter

If you notice that the machine is taking longer to fill,
check that the filter in the water inlet hose is not
blocked.
Turn off the water tap.
Unscrew the hose from the tap.
Clean the filter with a stiff brush.
Screw the hose back onto the tap.
P1090
12:27
Pagina 20
(Nero/Process Black pellicola)

Emergency emptying out

If the water is not discharged, proceed as follows to
empty out the machine:
• pull out the plug from the power socket;
• close the water tap;
• if necessary, wait until the water has cooled down;
• open the the pump door;
• place a bowl on the floor and place the end of the
• clean the pump if necessary as previously
• replace the emergency emptying hose in its seat
• screw the pump again and close the door.

Frost precautions

If the machine is installed in a place where the
temperature could drop below 0°C, proceed as
follows:
• Remove the plug from the socket.
• Close the water tap and unscrew the water inlet
• Place the end of the emergency emptying hose
• Screw the water inlet hose back on and reposition
By doing this, any water remaining in the machine is
removed, avoiding the formation of ice and,
consequently, breakage of the affected parts.
When you use the machine again, make sure that
the ambient temperature is above 0°C.
20
emergency emptying hose into the bowl. Remove
its cap. The water should drain by gravity into the
bowl. Whe the bowl is full, put the cap back on the
hose. Empty the bowl. Repeat the procedure until
water stops flowing out;
described;
after having plugged it;
hose from the tap.
and that of the inlet hose in a bowl placed on the
floor and let water drain out.
the emergency emptying hose after having put the
cap on again.