Servicing

A: Removal Of Hob Top
1. Remove all control knobs, pan supports, burner caps
and burner crowns.
2. Remove 2 screws for each burner.
3. Remove 6 fixing screws from the pan support hinges,
and remove the hinges from the hob.
4. Lift hob top at the rear and disengage it from the
front locators.
B: Removal Of the Hob Taps
(Isolate Electrical Supply)
1. Follow the procedures in Section A.
2. With the aid of a 7mm spanner remove the clamping
bolt from the fixing clamp.
3. Loosen the pipe connection nut from the gas tap with
the aid of a 16mm spanner. Remove fixing clamps.
4. Reassemble in reverse order and carry out leak test.
C: Removal Of Mains Terminal Block
(Isolate Electric Supply)
1. Follow the procedures in Section A.
2. Disconnect supply flex connections from terminal
block.
3. From the underside of the hob remove 1 self tapping
screw from the terminal block.
4. Reassemble in reverse order.

Technical Maintenance

Check at regular intervals the condition and
serviceability of the gas connection hose and pressure
regulator, if any is fitted; in case of malfunction, do
not repair but replace the whole faulty part.
To ensure a smooth and safe operation, it is necessary
to periodically grease the gas taps.
Act as follows:
1) Carry out steps 1 to 4 as explained in "Removal of
Hob Top" (see top of page).
2) Remove screws 1 and 2 (see diagram)
3) Remove the gas tap shaft and flange.
4) Slide out the Venturi tube, clean it thoroughly and
then apply a thin layer of grease of a non-soluble to
hydrocarbons type and suitable for gas taps.
5) Make sure that no axcess grease abstructs the gas
tap holes.
6) Refit everything very carefully following this pro-
cedure in reverse order.
D: Removal Of Burner
1. Follow the procedures in Section A.
2. With the aid a 12mm spanner loosen off the pipe
connection nut.
3. From the underside of the hob remove 2 self tapping
screws from the burner body.
4. Reassemble in reverse order and carry out leak test.
E: Removal of Ignitor
(Isolate Electrical Supply)
1. Follow the procedures in Section A.
2. Remove H.T. leads from the ignitor by pulling tab
connection off. Disconnect supply cable from the
ignitor unit.
3. With the aid of a pair of thin nose pliers, pull the
spring clip sideward off of the underside of the
ignitor
4. Reassemble in reverse order.
F: Removal of Ignitor Switch
(Isolate Electric Supply)
1. Follow the procedures in Section A.
2. Remove the fixing nut from the switch and remove
tab connections.
3. Reassemble in reverse order and check with wiring
diagram for correct reconnection.