Installation

WARNING!
Refer to Safety chapters.
Before the installation
Before you install the hob, write down the
information bellow from the rating plate. The
rating plate is on the bottom of the hob.
Model .......................................
PNC .........................................
Serial number ...........................
Important safety requirements
This hob must be installed in accordance with
the Gas Safety (Installation and Use)
Regulations (Current Edition) and the IEE
Wiring Regulations (Current Edition).
For appliances installed in the Republic of
Ireland please refer to NSAI- Domestic Gas
Installation I.S. 813 Current Editions and the
ETCI Rules for Electrical Installations.
10
B
MOD.
PROD.NO.
SER.NO
03 IT
DATA
MADE IN ITALY
C
MOD.
PROD.NO.
SER.NO.
0049
C. Stick it on instruction booklet.
Provision for ventilation
Detailed recommendations are contained in the
following British Standards Codes Of Practice:
B.S. 6172/B.S. 5440, Par. 2 and B.S. 6891
Current Editions.
The hob should not be installed in a bed sitting
room with a volume of less than 20 m³. If it is
installed in a room of volume less than 5 m³ an
air vent of effective area of 100 cm² is required.
If it is installed in a room of volume between 5
m³ and 10 m³ an air vent of effective area of 50
cm² is required, while if the volume exceeds 11
m³ no air vent is required.
However, if the room has a door which opens
directly to the outside no air vent is required
even if the volume is between 5 m³ and 11 m³.
If there are other fuel burning appliances in the
same room, B.S. 5440 Part 2 Current Edition,
should be consulted to determine the requisite
air vent requirements.