not come in touch with mobile parts or they are not
squeezed. Also be careful when the hob is put together
with an oven.
Important! It is important to install the elbow correctly,
with the shoulder on the end of the thread, fitted to the
hob connecting pipe.
Important! Failure to ensure the correct assembly will
cause leakage of gas.
Important! Make sure that the gas supply pressure of the
appliance obeys the recommended values.
Rigid connection:
Carry out connection by using metal rigid pipes (copper
with mechanical end).
Injectors replacement
1.
Remove the pan supports.
2.
Remove the caps and crowns of the burner.
3.
With a socket spanner 7 remove the injectors and re-
place them with the ones which are necessary for the
type of gas you use (see table in "Technical Data"
chapter).
4.
Assemble the parts, follow the same procedure back-
wards.
5.
Replace the rating plate (it is near the gas supply
pipe) with the one for the new type of gas supply.
You can find this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable or different from
the necessary pressure, you must fit an applicable pres-
sure adjuster on the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1.
Light the burner.
2.
Turn the knob on the minimum position.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-pass screw
position.
www.zanussi.com
1
The by-pass screw
1
– If you change from natural gas G20 20 mbar to
liquid gas, fully tighten the by-pass screw in.
– If you change from liquid gas to natural gas G20
20 mbar, undo the by-pass screw approximately
1/4 of a turn (1/2 of a turn for Triple Crown burn-
er).
Warning! Make sure the flame does not go out when
you quickly turn the knob from the maximum
position to the minimum position.
Electrical connection
• The electrical work necessary to install the appliance
must be done by a qualified electrician or competent
person, according to the current regulations.
• The appliance must be earthed.
• Always use a correctly installed shockproof socket.
• Make sure that there is access to the mains plug after
the installation.
• Do not pull the mains cable to disconnect the appli-
ance. Always pull the mains plug.
• The appliance must not be connected with an extension
cable, an adapter or a multiple socket. There is a risk of
fire. Make sure that the ground connection complies
with the standards and regulations force.
• The power cable must not touch any hot parts.
• The electrical installation must have an isolation device
which lets you disconnect the appliance from the
mains at all poles. The isolation device must have a
contact opening width of minimum 3 mm.
• You must have the correct isolation devices: line pro-
tecting cut-outs, fuses (screw type fuses removed from
the holder), earth leakage trips and contactors.
• The connection cable parts must not be heated to a
temperature above 90°C.