Zanussi ZGG66424 사용자 설명서 - 페이지 6

{카테고리_이름} Zanussi ZGG66424에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Zanussi ZGG66424 16 페이지. Gas hob
Zanussi ZGG66424에 대해서도 마찬가지입니다: 사용자 설명서 (16 페이지), 사용자 설명서 (16 페이지), 사용자 설명서 (21 페이지)

Zanussi ZGG66424 사용자 설명서
4. With a thin screwdriver, adjust the by-pass
screw position.
1
The by-pass screw
1
– If you change from natural gas G20 20
mbar to liquid gas, fully tighten the by-
pass screw in.
– If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2 of
a turn for Triple Crown burner).
Warning! Make sure the flame does not
go out when you quickly turn the knob
from the maximum position to the minimum
position.
Electrical connection
• The electrical work necessary to install the
appliance must be done by a qualified elec-
trician or competent person, according to the
current regulations.
• The appliance must be earthed.
• Always use a correctly installed shockproof
socket.
• Make sure that there is access to the mains
plug after the installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• The appliance must not be connected with
an extension cable, an adapter or a multiple
socket. There is a risk of fire. Make sure that
the ground connection complies with the
standards and regulations force.
• The power cable must not touch any hot
parts.
6
• The electrical installation must have an isola-
tion device which lets you disconnect the ap-
pliance from the mains at all poles. The isola-
tion device must have a contact opening
width of minimum 3 mm.
• You must have the correct isolation devices:
line protecting cut-outs, fuses (screw type
fuses removed from the holder), earth leak-
age trips and contactors.
• The connection cable parts must not be
heated to a temperature above 90°C.
Electrical Requirements
Permanent electrical installation must comply
with the latest I.E.E. Regulations and local Elec-
tricity Board regulations. For your own safety
the installation must be done by a qualified
electrician (e.g. your local Electricity Board, or a
contractor who is on the roll of the National In-
spection Council for Electrical Installation Con-
tracting [NICEIC]).
The manufacturer declines any liability if
these safety measures are not observed.
The appliance must be connected to a 230 V
50 Hz AC electrical supply.
Before activating the appliance, make sure the
electrical supply voltage is the same as that in-
dicated on the rating plate. The rating plate is
located on the bottom of the appliance.
The appliance is supplied with a 3 core flexible
supply cord with a 3 amp plug. If it is necessary
to change the fuse, use a 3 amp ASTA-ap-
proved (BS 1362) fuse.
www.zanussi.com