To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to the
voltage load and the working temperature. The
yellow/green earth wire (B) must be approxi-
mately 2 cm longer than the live and neutral
wire (A).
Warning! A cut off plug inserted into a 13
amp socket is a serious safety (shock)
hazard. Ensure that the cut off plug is disposed
of safely.
Important! The replacement of electric cable
must be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the current
regulations.
Building In
min. 600 mm
min. 100 mm
min. 55 mm
30 mm
12
A
B
min. 650 mm
550 mm
A) supplied seal
B) supplied brackets
Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
30 mm
A
min 20 mm
60 mm
(max 150 mm)
B
a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the indi-
cation and the kitchen unit must be equipped
with vents to let a continuous supply of air. The
electrical connection of the hob and the oven
must be installed separately for safety reasons
and to let easy remove oven from the unit.
50 cm
360 cm
B
2
120 cm
2
180 cm
www.zanussi.com
A
2
2