ADJUSTMENT OF MINIMUM LEVEL
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the bypass
screw position (A).
A
5. If you change:
•
from natural gas G20 20 mbar to liquid gas,
fully tighten the bypass screw in.
•
from liquid gas to natural gas G20 20 mbar,
undo the bypass screw approximately 1/4
of a turn.
WARNING! Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
•
Make sure that the rated voltage and type of
power on the rating plate agree with the voltage
and the power of the local power supply.
•
This appliance is supplied with a mains cable. It
has to be supplied with a correct plug which
can hold the load that the rating plate rates.
Make sure that you install the plug in a correct
socket.
•
Always use a correctly installed shockproof
socket.
•
Make sure that there is an access to the mains
plug after the installation.
•
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
•
There is a risk of fire when the appliance is in
connection with an extension cable, an adapter
or a multiple connection. Make sure that the
ground connection agrees with the standards
and regulations.
•
Do not let the power cable to heat up to a
temperature higher than 90° C.
12
Make sure that you connect the blue
neutral cable to the terminal with a
letter "N" on it. Connect the brown (or
black) phase cable to the terminal
which has a letter "L". Keep the phase
cable connected at all times.
CONNECTION CABLE
To replace the connection cable use only the
special cable or its equivalent. The cable type is:
H05V2V2-FT90.
Make sure that the cable section is applicable to
the voltage and the working temperature. The
yellow / green earth wire must be approximately 2
cm longer than the brown (or black) phase wire.
ASSEMBLY
1.
2.