Electrical Connection

The following instructions about installation
must be carried out by qualified personnel in
compliance with the regulation in force.
The appliance is designed to be connected to 230 V
monophase electricity supply.
The connection must be carried out in compliance with
the laws and regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation
can support the load (see the rating label);
2) check that the power supply is properly earthed in
compliance with the current rules;
3) check the socket or the double pole switch used for
the electrical connection can be easily reached with
the appliance built in the furniture unit.
The appliance is supplied with a connection cable. This
has to be provided with a proper plug, able to support the
load marked on the identification plate. To connect the
plug to the cable, follow the recommendation given in Fig.
5. The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The connection cable has to be placed in order that, in each
part, it cannot reach a temperature higher than 90 °C.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.
Replacement of the voltage cable
Only cable types H05V2V2-F T90 or H05 BB-F (section:
3 x 1,5 mm
) must be used.
2
The yellow/green earth wire must be approximately 2 cm.
longer than the phase wires (Fig. 6).
YES
FO 0238
FO 0073
RIGID COPPER PIPE OR
FLEXIBLE PIPE IN STAINLESS
STEEL
Fig. 5
Neutral
Earth (yellow/green)
Fig. 6
9