Zanussi ZHC 927 설치, 사용 및 유지보수 핸드북 - 페이지 7

{카테고리_이름} Zanussi ZHC 927에 대한 설치, 사용 및 유지보수 핸드북을 온라인으로 검색하거나 PDF를 다운로드하세요. Zanussi ZHC 927 13 페이지.

Zanussi ZHC 927 설치, 사용 및 유지보수 핸드북
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove any activated charcoal filters.
• Assemble the two halves of the hood body extension
piece 14.
• Push fit the assembled hood body extension piece 14
onto the air outlet.
• Push fit connection 15 onto the hood body extension
piece 14.
• Insert the connection extension pieces laterally 14.1
in connection 15.
• Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the
chimney outlets. If this is not the case, adjust the position by either reversing the connection extension
pieces 14.1 or by cutting the hood body extension 14 along one of the thinner section channels
denoting the pre-fixed lengths, then reassemble as described previously.
• The air outlet directional grills 8a - 8b must be fitted after the lower outlet duct 2.2 has been installed.
• Ensure that the activated charcoal filters have been inserted.
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
17
Connections

DUCTED VERSION AIR EXHAUST SYSTEM

RECIRCULATION VERSION AIR OUTLET

ELECTRICAL CONNECTION

GB