Clarke Air SP15ND 운영 및 유지 관리 지침 - 페이지 13

{카테고리_이름} Clarke Air SP15ND에 대한 운영 및 유지 관리 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke Air SP15ND 17 페이지. Engine driven

Clarke Air SP15ND 운영 및 유지 관리 지침
Unusual noise from
compressor.
Compressor
becomes too hot.
Bolts loose.
Flywheel loose.
Unit installed on an unsuitable
base.
Bearings, piston rings or cylinder
worn.
Valve broken.
Insufficient ventilation.
Oil level too low (check 2 or 3
times after stopping).
Fault in valves (machine not
stopping).
Blown head gasket (machine
not stopping).
Dirt on cooling fins or suction
filter.
Unit working at too high a
pressure.
Not fully unloading
Load genie partly blocked.
Compressor being
overworked and running
continuously.
- 13 -
Tighten bolts - see page 16.
Tighten flywheel.
Move unit to a more solid base.
Contact Clarke Service
Department
Contact Clarke Service
Department
See that sufficient air is supplied to
flywheel or fan of compressor and
that hot air is properly vented.
Fill with oil – see Page 10.
Contact Clarke Service
Department
Contact Clarke Service
Department
Clean cooling fins and suction
filter.
Contact Clarke Service
Department
Contact Clarke Service
Department
Contact Clarke Service
Department
Connect to a supplementary
compressor or install a larger
model.