Zanussi ZC 560 지침서 - 페이지 17

{카테고리_이름} Zanussi ZC 560에 대한 지침서을 온라인으로 검색하거나 PDF를 다운로드하세요. Zanussi ZC 560 22 페이지. Electrogas cooker 50x50

Zanussi ZC 560 지침서

INSTRUCTIONS FOR THE INSTALLER

ADVICE FOR SAFETY
Before installation ensure that the local
distribution conditions (gas nature and
pressure) and the pre-setting of the
appliance are consistent;
This appliance must be installed only in
a room with good ventilation;
The
adjusting
conditions
appliance are mentioned on the rating
plate;
This appliance is not connected to a flue
gas exhaust device. It has to be
installed and connected in accordance
with the rules in force. Special attention
should be granted to the applicable
disposal concerning ventilation;
This appliance is of y type, meaning that
the furniture units can exceed its height;
The neighbouring furniture panels has to
be heat proof or protected by such
material.
Connection to gas main
Check that the counter flow and the
diameter of piping are enough to supply
all the appliances of the installation
(take counsel with the gas distribution
company);
Check that all connections are tight;
Install an accessible and visible barrage
tap;
If you use a flexible pipe it has to be
easily inspected all along and must not
pass behind the appliance;
Change the flexible pipe little before its
expire date stamped on it.
17
Electric connection
Check that:
the power of the installation is enough;
the
supplying
conditions;
the diameter of the cables complies with
the installation rules;
the fix installation has a device with
of
this
contacts with omnipolar switch with a
minimum opening between contacts of
minimum3 mm.
Installation and maintenance have to be
made by a qualified person in accordance
with the regulations in force, which are:
Decision of 2
Technical and Safety Rules to be applied to
fuel gas and liquefied hydrocarburs in the
buildings.
Standard DTU 45-204
Gas Installation (former DTU no. 61-1 – Gas
Installation, April 1982 + annex no. 1 July
1984).
Departmental Sanitary Regulation.
Standard NF C 15-100 – Low Tension
Electric Installation.
We deny any responsibility in cases of
accidents or incidents caused lack of
grounding or missgrounding.
lines
are
in
nd
August 1977
good