INSTALLATION INSTRUCTIONS
WARNING: THIS APPLIANCE MUST BE
EARTHED
If your appliance has been damaged in transit,
contact your supplier immediately. DO NOT attempt
to install it.
Your appliance left the factory fully packaged to
protect it from damage.
packaging
and
damage
manufacturer cannot accept responsibility. Contact
your supplier for advice.
Once the packaging has been removed the appliance
should only be moved by hand. DO NOT use a sack
barrow or any other aid to lift the appliance as
damage may occur.
Connection to the electricity supply must be carried
out by a qualified electrician/competent person.
The electrical connection should be made using a
double pole isolating switch (cooker socket) with at
least 3mm contact separation in all poles. The cable
must have conductors of sufficiently high cross-
sectional
area
to
deterioration.
The recommended cross-section area is six square
2
millimetres (6.00mm
).
The cable should be routed away from potentially hot
areas marked by X. See Fig.1.
To move the appliance, open the oven door, and lift
the appliance by holding inside the top of the
compartment. See Fig.2.
This is a type Y appliance, which means it is free-
standing and can be fitted with cabinets on one or
both sides. It may also be fitted in a corner setting.
Side walls which are above hob level should be
protected by heat resistant non-combustible material
and MUST NOT be nearer than 40mm to the hob
side.
A nominal air gap of 2mm at either side of the
appliance is required to enable the appliance to be
moved into position.
Always ensure an air gap is maintained at hotplate
level. Tiles or other forms of deep wall covering
should not obscure this gap. See Fig.3.
Overhanging surfaces or a cooker hood should be a
minimum of 685mm above the hob. See Fig.4.
It is important to ensure that the appliance is level
after installation. Levelling feet are fitted to the
appliance to accommodate uneven floors.
If it is delivered without
has
occurred,
prevent
overheating
the
and
Fig.1.
Fig.2.
Fig.3.
Fig.4.
31