Clarke PEH15 운영 및 유지보수 지침 매뉴얼 - 페이지 8

{카테고리_이름} Clarke PEH15에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke PEH15 17 페이지. Air compressor electric motor driven

Clarke PEH15 운영 및 유지보수 지침 매뉴얼

GENERAL ARRANGEMENT

A. STATIONARY
NB: Must be mounted on Anti Vibration Pads
1
Air Compressor Pump
2
Electric Motor (or
3
Wire Guard
4
Pressure Switch
5
Pressure Gauge
6
Safety Valve
7
Ball Valve
8
Drain Tap
NOTE: On automatic machines (10 H.P). a solenoid valve is fitted to the
delivery pipe.
NOTE: On automatic machines (10 H.P), an Auto Star Delta (ASD) starter
is fitted, ready to be mounted to a wall or panel etc. It is
IMPORTANT to note that NO ADJUSTMENTS should be made to this
component. The ASD should be connected to a 3-phase supply
by a qualified electrician.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
9
Inspection Plug
10
Non-Return Valve
11
Air Bleed Valve
12
Oil Drain Plug
13
Saddle
14
Air Intake Filter
15
Oil Filler/Breather
16
Oil Level Sight Glass
8
Fig.2
Illustrative
purposes
only
17
18
19
Air Delivery Pipe
20
Air Bleed Pipe
21
Air Receiver
22
On/Off switch
23
Auto Air Bleed