Clarke PEVH11C50 운영 및 유지 관리 지침 - 페이지 11

{카테고리_이름} Clarke PEVH11C50에 대한 운영 및 유지 관리 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke PEVH11C50 16 페이지. Air compressor electric motor driven
Clarke PEVH11C50에 대해서도 마찬가지입니다: 운영 및 유지보수 지침 매뉴얼 (17 페이지)

Clarke PEVH11C50 운영 및 유지 관리 지침
SYMPTOM
Unusual noise from
compressor.
Compressor becomes Insufficient ventilation
too hot.
PROBABLE CAUSES
Bolts loose.
V-Belt flywheel or cooling
coil touching belt guard
Flywheel loose.
Unit installed on an
unsuitable base.
Bearings, piston rings or
cylinder worn.
Valve broken.
Bearings of electric motor
worn.
Oil level too low (check
2 or 3 times after stopping).
Wrong direction of
rotation.
Fault in valves (machine
not stopping).
Blown head gasket (machine
not stopping).
Dirt on cooling fins or
suction filter.
Unit working at too high
a pressure
Non-return valve partly
blocked.
Compressor being
overworked and
running continuously.
11
REMEDY
Tighten Bolts.
Find place of contact and
remedy fault.
Tighten flywheel.
Move unit to a more solid
base.
Contact Clarke Service
Department
Contact Clarke Service
Department
Contact Clarke Service
Department.
See that sufficient air is
supplied to flywheel or
fan of compressor and
that hot air is properly
vented.
Fill with oil - see Page 6.
Cooling air from flywheel
fan must blow against
compressor.
Contact Clarke Service
Department
Contact Clarke Service
Department
Clean cooling fins and
suction filter.
Contact Clarke Service
Department.
Clean or thaw out non-
return valve.
Use a larger compressor