BEFORE STARTING COMPRESSOR, CHECK:-

1. Compressor Pump Oil Level using (a) Dipstick (to level
marked) or (b) sight glass (see fig.1)
2. Automatic Control:- Pressure switch ON/OFF switch is in
the OFF position.
WARNING:
1. BEFORE STARTING COMPRESSOR, OPEN ALL OUTLET VALVES.
2. THE FOLLOWING START AND STOP INSTRUCTIONS MUST BE
FOLLOWED IN THE CORRECT SEQUENCE TO AVOID SERIOUS
DAMAGE TO THE COMPRESSOR/MOTOR.
TO START COMPRESSOR
1. Switch on isolator (mains supply)
2. Switch on pressure switch (lift knob or twist switch). (See "GENERAL
ARRANGEMENT" on page 8., item 22)
3. Check rotation (Flywheel/Fan blows air over pump)
4. Run compressor for 10 minutes with outlet valves open (first time of
operation only).
5. Close valves and check that pressure does not exceed maximum working
pressure (stamped on machine plate), if the pressure exceeds the
maximum working pressure stated, stop the machine (see below), vent the
system and contact the Clarke Service Department.

TO STOP COMPRESSOR

1. Switch off at the pressure switch (Push knob down or turn switch).
2. Isolate from the Mains Supply.
3. Drain air receiver (release drain tap).
WARNING: COMPRESSOR PUMPS, DELIVERY PIPES WILL REMAIN HOT FOR
SOME TIME AFTER USE.
NOTE: When starting compressors up to and including the 3HP models,
an auto bleed valve will operate and air will be heard vent. This is
quite normal and should not cause concern. The valve should
close after several seconds. Should it fail to close, consult your
Clarke dealer.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]