Clarke XEV16/200 운영 및 유지보수 지침 매뉴얼 - 페이지 10
{카테고리_이름} Clarke XEV16/200에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke XEV16/200 17 페이지. Electric motor driven
Clarke XEV16/200에 대해서도 마찬가지입니다: 운영 및 유지보수 지침 매뉴얼 (17 페이지), 운영 및 유지보수 지침 매뉴얼 (17 페이지)
TROUBLESHOOTING CHART
1. Any remedial work that may be required must be carried out by a qualified
electrician/engineer.
2. Disconnect from the mains supply before removing any parts from the
compressor.
3. Empty Air Receiver of Air before dismantling any part of the compressor
unit's pressure system.
4. If your compressor develops a fault do not use until the fault has been
rectified.
SYMPTOM
Compressor will
not start
automatically
Compressor unit
will not stop
automatically.
Fuses keep
blowing.
Bleed valve
under pressure
switch blows
whilst
compressor is
not running
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
IMPORTANT
PROBABLE CAUSE
Fault in electrical installation
Current supply failure.
Voltage drop.
Motor starter faulty.
Motor incorrectly connected or
faulty
Starter overload has
out.
Pressure switch defective.
Fuse blown.
Pressure switch defective.
Inadequate size fuse installed.
Fault in motor.
Non-return valve leaking.
!
REMEDY
Let an electrician check
electrical installation.
tripped
Reset by depressing button.
Have pressure switch
changed by an electrician.
Check fuse rating - replace.
Contact Clarke Service
Replace with reference to
chart See page 6.
Contact Clarke Service
Clean non-return valve or
replace.
10