SYMPTOM
Compressor's
oil
consumption
rising.
Oil in the air
delivered.
Oil level rises
although no
oil has been
put in.
Condensation
at outlet
points.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
PROBABLE CAUSE
Too much oil in compressor.
Leaks around crank case
Working temperature of
compressor too high because
of insufficient cooling.
Cylinder worn.
Intake air filter blocked
Sump over full
Cylinder worn
Intake air filter blocked
Condensation in oil pump.
Piping installation incorrect.
Compressor taking in air
which is too warm.
REMEDY
Check oil level 2 or
3 minutes after stopping.
Contact Clarke Service
Department
Increase ventilation to air
compressor.
Contact Clarke Service
Department
Clean or replace
Reduce oil to correct level.
Contact Clarke Service
Department
Clean / Change air filter.
Compressor over
dimensioned.
Consult your local dealer
Obtain better fresh-air
supply to compressor.
15