TROubLeShOOTING

ProbLem
The compressor stopped and
does not start.
The motor does not start and
makes a humming noise.
The motor does not start or starts
slowly.
The compressor is noisy with
metallic clangs.
.
12
PoSSIbLe cauSe
Overloaded because of motor overheating.
Motor windings are burned out.
Capacitor is burned out.
Low voltage supply to the motor.
Compressor head gasket broken or
valve plate faulty.
Compressor worn or broken piston ring
Compressor worn or broken cylinder ring
.
Customer Support: 1-866-409-4581
AIR COMPRESSOR
PoSSIbLe SoLutIonS
.
Check that the main voltage corresponds to
specifications. An extension cord that is too thin or
too long can cause a voltage drop and cause the
motor to overheat. Allow the motor to cool down.
use heavy duty extension cords. ensure that the
compressor is plugged into a socket as close as
possible to the consumer unit or fuse box.
Contact Customer Support.
Replace starter capacitor.
Check that the main voltage corresponds to
specifications. An extension cord that is too thin or
too long can cause a voltage drop and cause the
motor to overheat. Allow the motor to cool down.
use heavy duty extension cords. ensure that the
compressor is plugged into a socket as close as
possible to the consumer unit or fuse box.
Stop the compressor and contact the dealer.
Stop the compressor and contact the dealer.
Stop the compressor and contact the dealer.
.