California Air Tools 365 매뉴얼 - 페이지 6

{카테고리_이름} California Air Tools 365에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. California Air Tools 365 9 페이지. 5 gallon pressure pot with hvlp spray gun and hose

California Air Tools 365 매뉴얼
Trouble Shooting
WARNING:
If any of the following symptoms appears during your operating, stop using the tool immediately, or
serious personal injury could result.
Only a qualified persons or an authorized service center can perform repairs or replacement of tool.
Disconnect tool from air supply before attempting repair or adjustment. When replacing O-rings or
Cylinder, lubricate with air tool oil before assembly.
PROBLEMS
Air escaping from port on
regulator cap
Pressure dropping slowly
on gauge.
Fluid or air leak at the lid
gasket.
Paint in tank tends to
settle rapidly.
Gauge not registering air
pressure.
Safety valve popping off.
Note: Repairs should be carried out by a qualified person.
POSSIBLE CAUSES
Broken or damaged
diaphragm in regulator.
Dirty or work valve seat in
regulator.
Defective lid gasket.
Thumb screw not tight.
Paint not mixed or thinned
properly.
Defective air gauge.
Tank pressure to high.
Defective valve.
CORRECTION
Replace regulator
Replace regulator
Replace lid gasket.
Tighten thumb screws.
Mix or thin paint according to instruction on
paint.
Replace air gauge
Reduce tank pressure to 20-50 PSI.
Replace safety valve.