Electrical Connection

Before connecting the pump, check the voltage and phase supply required, this information
can be found on the junction box cover on top of the motor.
Installation should be carried out by a qualified electrician, using I.E.E approved cable and
fittings, and in accordance with I.E.E. Regulations. However, in the further interests of safety
we would emphasise the following,
Wiring Connections For Single Phase Models
Single phase pumps should be connected to a standard domestic 13 amp, 230 volt (50Hz),
electrical supply, we strongly recommend that the connection be made via a suitable
isolator switch and Residual Current Device (RCD).
IMPORTANT: Should the supply be taken from a normal 13 amp socket, then the plug used
must be to BS 1363 standard, and the wires should be wired up in accordance with the
following colour code:
Green & Yellow ............... Earth or marked with a letter "E" or Earth symbol "
Blue ................................... Neutral or terminal marked with a letter "N"
Brown ............................... Live or terminal marked with a letter "L"
Wiring Connections For Three Phase Models
Again installation should be carried out by a qualified electrician, using I.E.E cable and
fittings, and in accordance with I.E.E Regulations. To connect the cable to the motor see
electrical connections inside the terminal cover.
Delta Connection
L1
IF IN ANY DOUBT, contact CLARKE International Service on 020 8988 7400
WARNING: THIS PUMP MUST BE EARTHED.
Connections Within Terminal Box
L2
L3
Star Connection
L1
-6-
".
L2
L3